20A MiniPort remote sequencing accessory with IP control and EVS
Furman's Contractor Series MiniPorts extend the benefits of SmartSequencing to electronics outside of the equipment rack, providing tremendous flexibility to any installation scenario. Units may be daisy-chained and fully controlled via a Furman SmartSequencer, legacy Furman sequencer, third-party sequencers, and/or control and automation systems.
DIP switches and potentiometer allows customization of settings such as sequencing delays, 12V on/off, and more. Security covers are provided to prevent unauthorized personnel from tampering with DIP switches.
Sequencing of duplex initiated remotely by standard analog triggering (remote terminal) or data link (SmartSequencing from CN-1800S or CN-2400S).
The CN-20MP can shut itself off automatically when triggered by a fire alarm.
Caractéristiques
SmartSequencing? " SmartSequencing allows bidirectional, safe sequenced power up/down operations via the push of a button or turn of a key.
Voltage Protection " Extreme Voltage Shutdown (EVS) safeguards from catastrophic under-voltage (under 80V sustained) or over-voltage (over 145V sustained) conditions. The EVS feature can be selectively enabled or disabled according to the preference of the user.
Diagnostic Lights " Diagnostic lights provide valuable system information including power quality.
20 Amp Output Current " 20 amp maximum current capacity.
DIP Switch Customization " DIP switches and potentiometer allows customization of settings such as sequencing delays, 12V on/off, and more. Security covers are provided to prevent unauthorized personnel from tampering with DIP switches.
Spécifications
AC Voltage Input Range 90-139VAC, 50/60Hz
Maximum AC Current Rating 20 Amps (No Breaker)
AC Cord 3/12AWG, 10 feet, black, fixed, NEMA 5-20P plug
AC Receptacles 2 NEMA 5-20R's (1 duplex)
AC Undervoltage Protection EVS, 77VAC+/-3VAC
AC Overvoltage Protection EVS, 140VAC+/-5VAC
AC Overvoltage Reset Modes Enabled and disabled (configurable via DIP Switch #9)
Operating Temperature Range 5C (40F) to 40C (105F) degrees
Humidity Range <90% rH (Relative Humidity)
Circuit Breaker No Breaker
Front panel diagnostic indicators (LED) Power, Extreme Voltage, Primary Link, Secondary Link
Side Panel DIP Switch Features (with security cover) 1 Minute Delay, 2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off GND Mode On, Momentary/Maintained, Primary/Secondary, EVS Reset Auto/Manual
Side Panel Potentiometer allows fine tune delay adjustments