Shopping cart | Login |
English | Français
The entire Studio Economik's website is now priced in Canadian Dollars only.
HomepageMicrophonesCondensor Microphones › Oktava MK-012-10
Oktava MK-012-10

Universal studio multi-diaphragm condenser microphone set with four capsules (SMALL DIAPHRAGM - cardioid, hypercardioid, omni-directional; LARGE DIAPHRAGM - cardioid).

The wide, flat response ensures that all sounds are captured with a high degree of accuracy.

A -10 dB pad is included for use in high SPL environments, a low-cut pad is optionally available. The capsules, which screw onto the microphone body, utilise a precision, integral connection system to ensure reliable electrical contact.

The MK-012 is suitable for use in any situation where an accurate sound is required, the small size of the system makes it ideal for use in broadcast, sound for picture, installation, sound reinforcement and theatre situations as well as the recording studio.

  • 1 x microphone body (preamps)
  • 1 x cardioid capsules
  • 1 x hypercardioid capsules
  • 1 x omni-directional capsules
  • 1x large diaphragm cardioid capsule
  • 1 x -10dB pad
  • 1 x mic holder
  • 1 x plastic case
  • Specifications
    Mic type : Small diaphragm condenser
    Polar Pattern : Cardioid, Hypercardioid, Omnidirectional
    Freq. Response : 20-20000Hz
    Phantom voltage required : 48 +- 2V
    Full impedance, module : less than 300 ohms
    Weighted SPL (ref. DIN 45412) : 18 dBA
    Maximum SPL in 250-8000Hz range, (less than 0.5% THD) : 130 db
    Free field sensitivity at 1KHz : <10 mV/Pa
    Free field sensitivity roll off from 40Hz to 20KHz should not exceed : +- 3 db
    Weight with 3 capsules and pad : 200 gr
    Length, mm : 128
    Max diameter/width, mm : 23
    Accessories included : Mic holder
    The difference in free field sensitivity between 0° and 90° should be as follows:
    For omnidirectional capsule:
    in 40-1000 Hz range : no more than 2 db
    in 1-5 KHz range : no more than 4 db
    in 5-8 KHz range : no more than 8 db

    For cardioid capsule:
    in 250-8000 Hz range: : no less than 4 db

    For hypercardioid capsule:
    in 250-5000 Hz range: : no less than 8 db

    Average sensitivity difference between O° and 180° for cardioid capsule in 63-12500 Hz range: : 16 db
    Price *
    Free shipping in Canada. Conditions
    Additional information
    For more information about the MK-012-10, please visit the website of Oktava
    Oktava Logo
    ©2004-2016 - Systemes Guinois® Inc. All Right Reserved.